Jun 13, 2016· Optimizing interstitialvelocityon an existingdust collector. In an existingcollectorinstallation, too high interstitialvelocity canbe a difficult condition and expensive to remedy. Possible modifications to reduce interstitialvelocityinclude: Increase the open area in the filter housing by changing to smaller diameter bags

Get Price

News & List

  • understanding conveying velocities in dust collection

    understanding conveying velocities in dust collection

    (Figure 1) As an example, lead dust, which is relatively heavy, typically requires a minimum conveying velocity of4,500 feet per minute, whereas weld fume, which is much lighter, may require 2,000 – …

    Get price
  • figure dust collection needs by the numbers wood magazine

    figure dust collection needs by the numbers wood magazine

    Nov 03, 2016· The speed of air movement through a dust-collection system is critical. For systems carrying woodshop dust and chips, engineers recommend minimum air velocity of4,000 FPM in branch lines (that’s about a 45 mph breeze) and 3,500 FPM in the main duct. The speed of the air moving in the system may exceed these figures, but shouldn’t fall below them

    Get price
  • how to size ductwork for industrial dust collection systems

    how to size ductwork for industrial dust collection systems

    Heavy and moist dusts such as most cement, asbestos and limedust; ConveyingVelocityRequirements. It is also key to consider theminimumconveyingvelocity, referred to as TransportVelocity, that is required to move thedustwith particulates (dust, condensable vapors) without creating build-up, static or other obstacles to the airflow

    Get price
  • dust collection tips and guidelines to remember

    dust collection tips and guidelines to remember

    Oct 26, 2016· For most applications, the proper dust velocity is between3500 and 4000 fpm. If it goes lower than 3500 fpm then dust will fall out in the airstream. If it goes higher than 4000 fpm then it will result to duct abrasion, especially in the duct branches and elbows. Schedule a consultation with our team of experts, today. Call us at 11300721458

    Get price
  • baghouse terminology dust collector staclean

    baghouse terminology dust collector staclean

    Can Velocity: The theoretical speedof dustladen air as it passes upward between the filter bags. The formula for calculatingcan velocityis as follows: The square area of the baghouse (length x width) minus the area occupied by the bottom of the bags (the sum of the areas of the number of bags) divided into the volume of air in ACFM

    Get price
  • the importance ofsizing ductwork for dust collection

    the importance ofsizing ductwork for dust collection

    Steel grinding dust conveyed @ 3500 feet per minute (velocity). A typical grinder uses 500 cubic feet of air per minute (cfm) to control dust. To move this much air, select an appropriate size of ductwork – in this example, a 5-inch diameter duct yields just over 3500 feet per minute for 500 cfm air volume

    Get price
  • understanding conveying velocities indust collectors

    understanding conveying velocities indust collectors

    Figure 1 - To prevent the settling of dust within ductwork, an appropriate conveying velocity is necessary. As an example, lead dust, which is relatively heavy, typically requires a minimum conveying velocity of 4,500 feet per minute, whereas weld fume, which is much lighter, may …

    Get price
  • baghouseterminology dust collector staclean

    baghouseterminology dust collector staclean

    = 186.2 fpm can velocity . Capture Velocity: The air velocity at any point in front of the hood or at the hood opening necessary to overcome opposing air currents and to capture the contaminated air at that point by causing it to flow into the hood. Cloth weight: Usually expressed in oz./sq. yard

    Get price
  • dust collection system design part 2 transport velocity

    dust collection system design part 2 transport velocity

    The standard ductvelocitymay be appropriate for transporting lighter or drierdustparticles through the ductwork all the way to thedust collector. However, heavy or wetdustparticles will require a higher transportvelocityto prevent settling or plugging. Adust collectionsystem with multiple capture points will need branches in the

    Get price
  • designing an efficient dust collection system spiral

    designing an efficient dust collection system spiral

    You now have the information you need to specify your dust collector. Your dust collection unit must provide a minimum of 1880 CFM through a 10” duct at 4000 FPM, and have a static pressure capability of no less than 7.57 (˝wg). Additional Considerations and Recommendations The above example is for a small system with few variables

    Get price
  • evaluation of the can velocity effect ona bag filter

    evaluation of the can velocity effect ona bag filter

    Nov 01, 2017· Thecan velocity(Vcan) and gravitational settlingvelocity(V st)of dustparticles were calculated as follows (1) Vcan= Q in Acollector− N bag A bag (2) V st = μ ρ g D p exp − 3.07 + 0.9935 × ln 4 ρ p ρ g D p 3 g 3 μ 2 − 0.0178 × ln 4 ρ p ρ g D p 3 g 3 μ 2 2 where Q in is the flow rate of thedust collector, N bag is the number of installed bag filters.Acollectorand A

    Get price
  • the importance ofsizing ductwork for dust collection

    the importance ofsizing ductwork for dust collection

    Duct sizing is based on 2 variables: the particulate being collected and the volume of air being moved. The heavier the dirt, the higher the air velocity needed. Example. Steel grinding dust conveyed @ 3500 feet per minute (velocity). A typical grinder uses 500 cubic feet of air per minute (cfm) to control dust

    Get price
  • pneumatic transportand conveying carrying velocities

    pneumatic transportand conveying carrying velocities

    Air Carrying Velocity (lb/ft 3) (in H 2 O) (m/s) (ft/min) Ashes, powdered clinker: 30 - 43: 6500 - 8500: Ashes from coal: 30: 3: 28: 5500: Beans: 28: 4: 31: 6000: Buffing dust: 2.5: 19: 3700: Cement: 100: 5: 30 - 46: 6500 - 9000: Coal, powered: 20 - 28: 4000 - 5500: Coffee beans: 15 - 20: 3000 - 4000: Cork: 14: 1.5: 17 - 28: 3000 - 5500: Corn, wheat, rye: 45: 3.5: 25 - 36: 5500 - 7000: Cotton, dry: 5: 2: 22 - 30: 3500 - 6500: Flour: …

    Get price
  • duct velocity vs particle size dust load

    duct velocity vs particle size dust load

    Dec 10, 2009· referring to acgih manual, for cement dust the recommended duct velocity is ranging from 18-20m/s but i have tested few duct with velocity below 10m/s eg venting cement silo, still can trasnport the cement dust without experience any blockage since 1977. so acgih guideline to me it seems to high or maybe not taking dust load/size into consideration

    Get price
  • best practices for the design and operation of coalmill

    best practices for the design and operation of coalmill

    Oct 07, 2019· Can velocity Defined as the upward velocity of dust-laden gases between filter bags, excessive can velocity can result in higher pressure drop and excessive dust accumulation. For a coal mill dust collector, velocity should not exceed 240 fpm or 1.22 m/s

    Get price
  • dust collectorsizing what size do you need

    dust collectorsizing what size do you need

    Aug 22, 2018· Depending on the dust characteristics, the correct CFM value should be approximately 100–200 feet per minute of air velocity multiplied by the cross-sectional area of the hood in square feet. Accurate measurement of the volume of air going through the baghouse is vital for adequate ventilation